Tiger Handheld VOC gas detector

The Tiger handheld VOC gas detector is a revolutionary handheld, portable PID instrument for rapid, accurate detection of volatile organic compounds (VOCs).

Our handheld VOC gas detector incorporates ION Science patented photoionisation detection (PID) sensor technology with humidity resistance and anti-contamination design, proven to dramatically extend run time in the field.

Features

The Tiger handheld VOC gas detector provides a dynamic detection range of 0 to 20,000 parts per million (ppm) with a minimum sensitivity of 0.001ppm (1 ppb), offering the widest measurement range of any other VOC detector on the market. This portable, handheld detector has the fastest response time on the market of just two seconds and is just as quick to clear down.

Tiger has been designed for the safe replacement of batteries in hazardous environments. Long-life rechargeable Li-ion batteries give up to 24 hours of use. Fast battery charging allows the instrument to be fully charged in 6.5 hours, while 8 hours of use can be achieved from 1.5 hours charge.

Other instruments in the Tiger range of handheld VOC gas detectors include the low-cost Tiger LT, and the Tiger Select for total aromatic compounds, including benzene.

 

Technical Specification

etl_certificationkgs_certificationIECEx certificationATEX certfication

 

 

Minimum Resolution:

- 10.6 eV: 1 ppb or 0.001 mg/m3***
- 11.7 eV: 0.6 ppm (600 ppb)***

Detectable Range:

- 10.6 eV: 1 ppb up to 20,000 ppm***

1- 1.7eV: 9,000 ppm***#

Response Time:

- 10.6 eV: T90 < 2 seconds

- 11.7eV: <6 seconds

Accuracy:

- 10.6 eV: ± 5 % display reading ± 1 digit***

- 11.7 eV: ± 12 % display reading***

Battery Life:

- Li-ion: life up to 24 hours, charge time 6.5 hours
- Alkaline: 3 x AA, typically 8.5 hours life

Lamps:

- 10.6 eV Krypton PID lamp (standard)
- 10.0 eV and 11.7 eV available

Data Logging: 120,000 points including date and stamp

Calibration: 2 point and 3 point calibration (via calibration kit accessory)

Alarm:

- Flashing LEDs Amber (low alarm) Red (high alarm)
- Sounder 95 dBA at 300 mm (12″)
- Vibration on alarm
- programmed TWA and STEL*

Flow Rate: ≥ 220 ml/min (with blocked flow alarm)

Temperature:

- Operating:
10.6 eV: -20 to 60 °C, -4 to 140 °F (non Intrinsically Safe)
11.7 eV: 0 to 60 °C
- Certified to:
10.6 eV: 15 to +45 °C / +5 to 113 °F (Intrinsically Safe environment)
11.7 eV: 15 to +45 °C / +5 to 113 °F (Intrinsically Safe environment)
- Storage:
-25 to 60 °C / -5 to 140 °F
Humidity: 0-99% RH (non condensing)

Protection:

Designed to IP65 (heavy rain)
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A

Weight & Dimensions:

Instrument (with probe)
Width: 340 x height 90 x depth 60 mm (13.4 x 3.6 x 2.4″)
Standard case: 367 x 89 x 90 mm (14.45 x 3.54 x 2.36″)
Instrument weight 0.72 kg (1.56 lb)
Packed weight: 5.5 kg (12lb)

 